• Home
  • /
  • Categories
  • /
  • Energy Stationary Storage
  • /
  • Toward Rigorous Safety Evaluation and Active Thermal Runaway Mitigation: Accommodating Cell Variation and Non-Monotonicity in Emergency Discharge
Energy Stationary Storage
Insights

Toward Rigorous Safety Evaluation and Active Thermal Runaway Mitigation: Accommodating Cell Variation and Non-Monotonicity in Emergency Discharge

By Peng Zhao, Associate Professor of Mechanical and Aerospace Engineering, University of Tennessee Space Institute

Toward Rigorous Safety Evaluation and Active Thermal Runaway Mitigation: Accommodating Cell Variation and Non-Monotonicity in Emergency Discharge

With the fast expansion of electric vehicle and energy storage markets, development and safety of lithium-based and the next-generation of batteries have attracted extensive interest. Due to inherent thermal stability, a charged battery contains components that can react with each other under elevated temperature conditions, as can be triggered from mechanical, electrical and thermal abuse. This process is typically referred to as thermal runaway (TR), due to the positive feedback between the temperature and heat release rate, and is frequently accompanied by smokes and fires. As such, it is critical to rigorously evaluate the safety threshold of a certain type of cell, and hopefully, an active mitigation strategy can be developed to suppress its occurrence based on cell characteristics.

Batteries are like humans, due to the facts that they have a “preferred” temperature range for reliable operation, and that they all experience capacity fading after many cycles, and also that every single cell have slight differences potentially due to manufacturing inconsistency which sensitively affects their safety behavior. Such cell variation is omnipresent even in fresh cells, and necessitates statistical analysis and uncertainty quantification in safety assessment and battery management system (BMS) development. However, it is not sufficiently considered and addressed in existing battery systems and testing procedures. Our previous work revisited thermal runaway testing and modeling over the extensively investigated, relatively better-understood 18650 cylindrical cells with lithium cobalt oxide (LCO) chemistry, using a well-calibrated facility extended-volume accelerating rate calorimeter (EV+ ARC) following the heat-wait-seek strategy (HWS) step-heating strategy. By repeating the experiment for multiple similar cells with near-identical initial conditions, we found that thermal runaway is highly sensitive to cell-to-cell variations at birth, even though all cells exhibit near identical electrochemical performance during cycling. The testing results exhibit variation in exothermicity onset, thermal runaway onset, maximum temperature rise, peak temperature, mass loss, and thermal runaway delay time, as directly shown in the temperature evolution in Fig. 1. The key insight here is that safety evaluation of a certain cell type should be based on the statistical behavior of sufficient number of similar cells, rather than individual tests. 

Furthermore, cell variation provides key statistical features to inform the design of a reliable BMS. More recently, statistical analysis over 20 independent ARC testing data on 18650 lithium iron phosphate (LFP) cells have shown that the voltage-drop temperature associated with separator shutdown) before TR occurrence is a cell-characteristic random variable that follows a normal distribution, as shown in This intrinsic feature rooted in cell variation can be leveraged to define a probabilistic criterion based on discharge-termination temperature for active thermal runaway mitigation and risk control, where successful TR mitigation must rely on TDT <= TVD, in that any stranded energy beyond this point cannot be discharged and hence will aggravate TR heat release and subsequent fires. This criterion allows active control of the probability of complete discharge, and hence the likelihood of subsequent thermal events. Cell variation can accumulate during usage and aging. For assessment of used and second-life batteries, a routine practice is to compare and correlate cell safety characteristics based on the widely adopted metric, state of health (SOH), as defined by the normalized capacity. While SOH effectively describes extent of capacity fading, it fails to include information on internal material change following different usage history. As such, SOH alone is fundamentally insufficient to correlate safety behavior of degraded cells. Our previous work has demonstrated substantial difference in the safety threshold of cells following different aging history, even with new mode in thermal runaway occurrence. For cells with dominant aging mechanism of Li dendrite and plating as stimulated from low-temperature cycling and fast charging conditions, thermal runaway is substantially facilitated from localized heat sources from reactions involving the dendrite and can exhibit the hotspot-induced ignition nature of thermal runaway. This is fundamentally different from the volumetric, homogeneous thermal runaway mode with near-uniform heat release. Other aging mechanisms, such as thickening of solid-electrolyte interface, mechanical fracture in electrodes, can each introduce distinct internal material and structure changes within the cell and hence lead to different TR performance and structure-property mapping. Therefore, there is an urgent need to understand cell variation from degradation and its effect on the change of safety characteristics.

A promising technology to mitigate risk of thermal runaway and its propagation is emergency discharge, which bears similarity to the prescribed burning concept in wildfire prevention, where the amount of the materials that can participate in thermal runaway is reduced as the cell gets discharged. An important consideration for emergency discharge is that it can lead to inherent competition between increased temperature and reduced state of charge (SOC), with opposite effects in TR triggering. Specifically, with ohmic and entropy heat during discharge, a cell’s temperature can be substantially elevated, which facilitates TR; while the reduced SOC will attenuate TR. In addition, fast emergency discharge requires a battery to operate at conditions beyond exothermicity onset, and even around the venting limits. As pointed out by Ebrahimi et al, this is a domain where battery control algorithms and management systems remain in infancy, and hence urgently requires guidance from testing data. Common manufacturer-suggested thermo-electrochemical constraints typically available in a user manual, such as voltage, current, and SOC limits to prevent overcharge and overdischarge, as well as temperature limits

Taking advantage of the near adiabatic environment provided by the accelerating rate calorimetry (ARC), our recent testing data have shown that emergency discharge does not always work and can even directly trigger thermal runaway due to either high stranded energy or extremely high ohmic heating. As shown in Fig.2, the effectiveness of emergency discharge in preventing thermal runaway is a non-monotonic function of discharge rate, such that both excessively low and excessively high discharge rates fail to prevent thermal runaway while an intermediate range succeeds at a given discharge temperature. Similar regime boundary needs to be established for representative cell chemistry, state of charge, and state of health following similar approaches to directly guide emergency discharge.

practical implementation of emergency discharge for extreme scenarios such as stranded batteries after an accident, additional heat sources near the discharging cells must be considered, which can include heat release from a nearby cell with thermal runaway, local short circuit, parallel connection, and strong self-discharging. Such heat sources place fundamental competition to determine the stranded energy in the discharge cell, via thermal energy gain and electrical energy loss, which have opposite effects on thermal runaway occurrence. Our recent research has shown the existence of a critical discharge rate for a given heating rate, below which thermal runaway cannot be mitigated (Fig. 3a). Also, the results have suggested inherently higher sensitivity of thermal runaway occurrence to heat gain than electricity discharge. Specifically, more than 3 units of electricity need to be discharged per each unit of heat input, as shown in Fig. 3b. These new insights need to be adopted in the next generation of BMS to mitigate thermal runaway propagation in practical transportation scenarios with extreme safety concerns.

Battery safety is an essential challenge in the era of electrification, which directly threats lives and property. The take-home message from this technical monograph is three-fold: first, cell variation should and must be considered for thermal runaway testing, prediction and for discharge protocols; second, emergency discharge does not always work, and it can directly trigger TR if the discharge condition falls out of the safety regime diagram; last but not least, TR is inherently more sensitive to heat input, which will shift the safety condition for emergency discharge with the existence of external heat sources.

  • By Peng Zhao
  • 2026-11-20